Fleck® Top Mount Fiberglass Filters

VIP-1E Control – Simplex Carbon Filters

Fiberglass Tank - Simplex

Features:

  • Simplex tank operation. Unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

VIP-1E Control – Duplex Alternating Carbon Filters

Fiberglass Tank - Alt 2

Features:

  • Twin alternating operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature
  • Optional: VIP-2E triplex and/or quadraplex units available.

VIP-1E Control – Duplex Parallel Carbon Filters

Fiberglass Tank - Par2

Features:

  • Duplex parallel operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • Par 2 - Systems offer one single pipe size larger flow meter!
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature
  • Optional: VIP-2E triplex and/or quadraplex units available.

Time Clock – Simplex Carbon Filters

Fiberglass Tank - Simplex TC

Features:

  • Automatic time clock initiated backwash.
  • Unfiltered Water bypass during backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

Time Clock – Duplex Carbon Filters

Features

  • Automatic time clock initiated regeneration.
  • No Unfiltered Water bypass during regeneration.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

VIP-1E Control – Simplex Multi-Media Filters

Fiberglass Tank - Simplex

Features:

  • Single tank operation. Unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid State single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

VIP-1E Control – Duplex Parallel Multi-Media Filters

Fiberglass Tank - Par 2

Features:

  • Duplex parallel operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow meter, resettable totalizing meter & self diagnostic status monitoring. NEMA enclosed controller.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • Par 2 - Systems offer one single pipe size larger flow meter!
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

Time Clock – Simplex Multi-Media Filters

Fiberglass Tank - Simplex TC

Features:

  • Automatic time clock initiated backwash.
  • Unfiltered water bypass during backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

Time Clock – Duplex Multi-Media Filters

Fiberglass Tank - Duplex TC

Features:

  • Automatic time clock initiated backwash.
  • No unfiltered Water bypass during regeneration.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • >
  • ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

VIP-1E Control – Simplex Greensand Plus Filters

Fiberglass Tank- Simplex

Features:

  • Single tank operation. Unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow meter, resettable totalizing meter & self diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

VIP-1E Control – Duplex Alternating Greensand Plus Filters

Fiberglass Tank - Alt 2

Features:

  • Twin alternating operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow meter, resettable totalizing meter & self diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

VIP-1E Control – Duplex Parallel Greensand Plus Filters

Fiberglass Tank - Par 2

Features:

  • Duplex parallel operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow meter, resettable totalizing meter & self diagnostic status monitoring. NEMA enclosed controller.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • Par 2 - Systems offer one single pipe size larger flow meter!
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.

Time Clock – Simplex Greensand Plus Filters

Fiberglass Tank - Simplex TC

Features:

  • Automatic time clock initiated backwash.
  • Unfiltered water bypass during backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

Time Clock – Duplex Greensand Plus Filters

h4>Fiberglass Tank- Duplex TC

Features:

  • Automatic time clock initiated backwash.
  • No unfiltered Water bypass during regeneration.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH operation.

VIP-1E Control – Duplex Alternating Multi-Media Filters

Fiberglass Tank - Alt 2

Features:

  • Twin alternating operation. No unfiltered water bypass during backwash.
  • VIP-1E electronic metered or time clock feature & UL listed.
  • Solid state single metered demand initiated backwash including rate of flow meter, resettable totalizing meter & self diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash.
  • Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston.
  • ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks.
  • 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage.
  • Optional: Differential pressure backwash feature.
  • Optional: VIP-2E triplex and/or quadraplex units available.